Triad 56% Chamfer Airflow Panels

1500-5000 lbs Load Rating - Fit All Design

  • Overview
  • Specifications
  • Finishes
  • Detail

Triad's patented Chamfer Airflow panels are designed with our proprietary River Cooling System©, to provide optimal data center and server farm hot spot cooling for any imperial or metric raised floor systems that have maximum stringer width of 1.75”.

These panels are built to provide 1500 to 5000 lbs. of concentrated load capacities while versatile enough to be adjusted with the patent pending corner adapters either vertically or horizontally to flush mount to most all imperial or metric raised floor systems, regardless of age.

The patent pending Integrated Dual Handles provide safe, balanced lifting and placement of panel without danger of trapping fingers or toes while eliminating the need to search for suction cup lifters.

COMX's Hi-Plume Stratification Fin provides increased upper server cooling dropping upper/middle/lower server temperatures 5-15 degrees while lowering energy consumption 4% for every degree.

Model

Load Rating

Available Features

Compatibility

15TCF
30TCF
40TCF
50TCF

*1500 lbf
*3000 lbf
*4000 lbf
*5000 lbf

Dual Handles
Horizontal & vertical levelers

Size: 24" x 24"

Hi-Plume Stratification fin
Row Damper
OPD Damper
PowderPlate finish
(8 available colors)

Compatible with all new or existing raised floor systems.

15TCM
30TCM
40TCM
50TCM

*680 kgf
*1360 kgf
*1493 kgf
*2260 kgf

Using AVDP conversion

Dual Handles
Horizontal & vertical levelers

Size: 600 x 600 mm

Hi-Plume Stratification fin
Row Damper
OPD Damper
PowderPlate finish
(8 available colors)

Compatible with all new or existing raised floor systems.

The colors in this chart are ONLY displayed to give the viewer an overview of the color and finish selections available. Due to variances in computer monitors (such as color resolution, color temperature, etc.), video cards, color printers, and dye lots these files may not match exactly to the final delivered finish.

Powder coat finishes may vary between 3-5 mill thicknesses. Available in conductive and non-conductive, epoxy or urethane finishes. Chemical and abrasion resistance depends upon materials utilized.

Airflow Stratification Comparison

As is sTriad Airlfow Stratification Comparisoneen on the video Triad’s patented Hi-Plume Stratification fins, coupled with Triad's River Cooling System©, directs cooler air from the lower open plenum (where air normally passes by standard design airflow panels) to the upper heat stratified plenum of server racks.

The turbulent air delivery created by the patented Hi-Plume Stratification fin mixes with the vertical and horizontal heat boundary layers causing improved balanced cooling for the operating equipment.

Airflow Utilization Efficiency© (AUE) is measured by comparing the supply air temperature (65) to the temperatures at the top of the rack (80) = AUE of 15. By managing to an AUE of 10 or lower, data center managers can reduce cooling costs by up to 40%.